0-2000°C RESEARCH MATERIAL & HEATING TREATMENT'S LEADER
Ask for a free consultation Ask for technical supportModel | PT-1200T-V50 |
Heating zone length | 400mm |
Furnace tube size | diameter 50*900mm |
Furnace tube material | High-purity quartz tube with built-in 0.2mm quartz porous plate (customized) |
Working temperature | ≦1100℃ |
Max.temperature | 1200℃ |
Temperature measuring element | K type thermocouple temperature measurement |
Temperature Control System | Intelligent 30-segment PID microcomputer programmable automatic control and automatic tuning function |
Temperature control accuracy | ±1℃ |
Temperature control protection | With over-temperature and burnout protection function |
Heating rate | 0-20ºC/min |
Heating element | Alloy resistance wire |
Operating Voltage | AC 220V single phase 50HZ |
Maximum power | 3KW |
Furnace material | Polycrystalline fiber furnace material is used, which has good thermal insulation performance, high reflectivity and balanced temperature field. |
Flange | Stainless steel vacuum flange, easy to disassemble |
Sealing system | The furnace tube and flange are sealed by O-ring extrusion, which is easy to remove, can be removed repeatedly, and has good air tightness. |
fluidized area | 1. The reaction gas passes through the reaction zone evenly 2. The solid particles are suspended in the heating zone by the introduced gas. 3. The furnace body is designed to be open. When the experiment is completed, the furnace body can be opened, the quartz tube taken out, and the reacted particles taken out. Note: When gas is introduced to suspend sample particles, the particles may pass through the heating zone because the gas flow is too large. Therefore, the gas flow must be adjusted according to the size of the particles during the experiment. |
Shell structure | Double-layer shell structure with air cooling system, open type |
Furnace structure | vertical structure |
Furnace shell temperature | ≤45℃ |
Measurement and control equipment section | |
Name | Two-way mass flow meter |
Gas line | Second line |
flow control | Digital display, each gas channel contains a needle valve for individual control |
Link method | Double ferrule connector |
flow meter | Mass flowmeter |
Flow range | MFC1:N2 0-10SLM MFC2:CO2 0-10SLM |
Mixed air | Contains a precision air mixing tank |
Power supply | 220V 50HZ |
Working temperature | 5℃-45℃ |
Standard accessories | One set of main unit, 1 pair of high-sealing flanges, 1 quartz tube, 4 sealing rings, 1 pair of high-temperature gloves, 1 crucible hook, 1 flange hex wrench, 1 warranty card instruction |
We provide 24/7 hours global online service, one-stop customized service, welcome to consult.