Product numbervliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
PT-A1700-8L-DZvliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
Furnace structurevliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
Double-layer shell structure, equipped with a cold air system to automatically cool the furnace shellvliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
Furnace materialvliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
High-quality and high-purity alumina polycrystalline fiber curing furnace, with good insulation performance, high reflectivity and balanced temperature fieldvliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
Maximum temperaturevliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
1700°CvliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
Operating temperaturevliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
≤1600℃vliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
Heating ratevliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
Recommended ≤10℃/minvliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
sizevliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
200*200*200mm, width * height * depth)vliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
Temperature Control SystemvliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
It has PID adjustment and self-tuning functions and can compile 30 steps of temperature rise and fall programs;vliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
Heating elementvliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
High temperature silicon molybdenum rodvliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
Temperature measuring elementvliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
Type B thermocouplevliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
interfacevliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
The furnace is equipped with inlet, outlet and vacuum ports, and there are float flow meters and mechanical vacuum pressure gauges on the gas pathvliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
Sealing systemvliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
The furnace door and roof are sealed with high temperature silicon rubber. The furnace has air inlets and outlets for gas and vacuumvliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
Gas linevliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
One nitrogen float flow meter, one hydrogen float flow metervliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
Power supplyvliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
AC220V, 50/60HzvliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
rated powervliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
8KWvliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
Door opening methodvliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
Side doorvliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
Vacuum pumpvliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
VRD-8 rotary vane pump pumping speed 2.2L/SvliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
Ultimate vacuumvliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
-0.1MPavliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
Exhaust gas treatment devicevliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
The hydrogen combustion device can automatically ignite the eliminated hydrogenvliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
The standard configurationvliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
1 crucible tongs, 1 pair of high temperature gloves, 1 manual, 1 certificate of warranty cardvliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
RemarksvliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|
Please pay special attention: H2 is a particularly flammable and explosive gas. Its combustion temperature is 400℃. It will explode when the mixing ratio with air reaches 4.0%-74.2%, so safety measures must be taken when using hydrogen.vliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
The maximum pressure that can withstand in the furnace is 0.03MPa, so a pressure reducing valve must be installed on the gas cylinder when gas is introduced into the furnace.vliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Before introducing hydrogen, inert gas must be used to clean the furnace. The pressure inside the furnace should always be kept between 0.01-0.02 Mpa during use to prevent air from flowing back into the furnace and causing an explosion.vliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
The room where the equipment is placed must be well ventilated.vliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
The discharged hydrogen must be combusted indoors (the top of the furnace body is equipped with an automatic ignition device) In order to keep the pressure in the furnace chamber relatively stable during the heating process, we recommend that the equipment increasevliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Temperature rate is less than 10℃/minvliMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
|