Product name | High temperature tube cracking furnace |
Model | PT-T1200-S60LK |
Furnace chamber material | Alumina polycrystalline fiber |
Furnace tube size | Φ60mmX1000mm |
Heating zone length | 440mm |
Working temperature | 1100℃ |
Max.temperature | 1200℃ |
Temperature Control System | The temperature control system adopts artificial intelligence adjustment technology, has PID adjustment, self-tuning function and can compile 30 stages of temperature rise and fall programs; 1. Adopt PID method to adjust temperature control, and can set 30 heating and cooling programs 2. Temperature control accuracy ±1ºC 3. With over-temperature protection and broken couple protection, the electric furnace heating circuit will be automatically cut off when the temperature is over or broken The ON light on the panel is off, the OFF light is on, limited protection of the electric furnace). 4. The instrument has the function of temperature self-tuning |
Heating rate | 0-20ºC/min ,10ºC/min is recommended |
Heating element | Molybdenum resistance wire |
Operating Voltage | AC 220V Single phase 50HZ |
heating power | 3KW |
Furnace tube material | Quartz tube |
Flange joint | With stainless steel flange, installed mechanical pressure gauge and stainless steel shut-off valve |
sealing system | The furnace tube and the flange are squeezed and sealed with a silicone O-ring, which is easy to remove, can be removed repeatedly, and has good air tightness. Air inlet and outlet are reserved |
Rotameter | Float flowmeter can be installed at the inlet and outlet |
Additional configuration | Water cooling collection device can be installed |
After-sales service | 12-month warranty, lifetime warranty (heating elements, furnace tubes and other random gift accessories are not covered by the warranty) |
Precautions | 1.The pressure in the furnace tube should not be higher than 0.02MPa. 2.Due to the high internal pressure of the gas cylinder, when the gas is fed into the furnace tube, a pressure reducing valve must be installed on the gas cylinder, which will be more accurate and safe during use. 3.When the temperature of the furnace body is higher than 1000°C, the furnace tube cannot be in a vacuum state, and the air pressure in the furnace tube must be equal to the atmospheric pressure and kept at normal pressure. 4.The gas flow rate entering the furnace tube must be less than 200SCCM to avoid the impact of the cold atmospheric flow on the heated quartz tube. 5. The long-term service temperature of the quartz tube is less than 1100°C. 6.For sample heating experiments, it is not recommended to close the exhaust valve and inlet valve at the flange end of the furnace tube. If you need to close the gas valve to heat the sample, you need to always pay attention to the indication of the pressure gauge. If the pressure indication is greater than 0.02MPa, you must immediately open the vent valve to prevent accidents (such as furnace tube rupture, flange flying out, etc.). |
We provide 24/7 hours global online service, one-stop customized service, welcome to consult.