How to choose the temperature measuring element of high temperature furnace

How to choose the temperature measuring element of high temperature furnace:
high temperature furnace
1. What kind of temperature measuring element is usually used in high temperature furnace?xESMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
xESMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Thermocouples are commonly used as temperature measurement elements in high-temperature furnaces. According to different temperature grades, K, S and B are usually used.xESMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
xESMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
2. What is the difference in the temperature measurement range of thermocouples for different scales of high-temperature furnace heat?xESMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
xESMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
Class K thermocouples are generally used in high temperature furnaces below 1100°C, class S thermocouples are generally used in high temperature furnaces below 1400°C, and class B thermocouples are generally used in high temperature furnaces below 1800°C.