Technical parameter: | |
Model | PT-T1000-H100 |
structure | Double-layer shell structure, equipped with a cold air system to automatically cool the temperature of the furnace shell does not exceed 50 ℃ |
Furnace material | The high-quality and high-purity alumina polycrystalline fiber curing furnace made by Japanese technology vacuum adsorption molding has good insulation performance, high reflectivity and balanced temperature field. |
Maximum temperature | 1000℃ |
Heating rate | recommended to be ≤10℃/min, the fastest heating rate is 20℃/min |
Furnace tube material | 310S stainless steel tube |
Furnace tube size | Outer diameter: 102mm* wall thickness 10mm* length 1000mm The instrument must be plugged before use to prevent heat radiation |
Heating zone length | 440mm |
Flange | Two CF-100 flanges are welded at both ends of the furnace tube, Use oxygen-free copper sealing ring to seal, good sealing performance, flange Cover water-cooled structure, flange with positive and negative mechanical pressure gauge, stop valve and pressure sensor, pressure relief valve, etc. |
Pressure sensor | Digital pressure gauge, measuring range: 0-1MPA, can set a high pressure value and low pressure value manually, when the pressure in the tube exceeds this range, the alarm light will flash |
Pressure relief valve | Automatic pressure relief valve, which can set the pressure value. When the set pressure range is exceeded, the pressure relief valve will automatically vent to the set pressure value. |
Applicable pressure range | 0.4MPa at 900℃ |
Temperature control system | The temperature control system adopts artificial intelligence adjustment technology, has PID adjustment, self-tuning functions, and can program 30 sections of temperature rise and fall programs; 1. Using PID method to adjust the temperature control, 30 sections of temperature rise and fall programs can be set 2. Temperature control accuracy ±1ºC 3. With over-temperature protection and broken couple protection 4. The instrument has the function of temperature self-tuning Heating element Molybdenum alloy resistance wire |
Heating element | Molybdenum alloy resistance wire |
Temperature measuring element | K-type thermocouple |
Working power supply | AC220V,50/60Hz |
Rated power | 5KW |
Air inlet and outlet | There are vacuum connection ports on the flange, air inlet and outlet |
Flowmeter | Three-way float flowmeter is installed on the top of the box |
Vacuum pump | DRV10 rotary vane pump, pumping speed 2L/S Digital display vacuum gauge: resistance silicon measurement, display range atmospheric pressure--1.0*10-1Pa KF25 flapper valve + KF25 bellows |